CALL 1300 734 970 OR CONTACT US

  • About Us
  • Why Us?
  • FAQs
  • Downloads
  • Contact Us
  • Home
  • Services
  • Shop
  • Why Us?
  • Contact

OUR SERVICES

  • Appliance Test & Tag
  • Thermal Imaging
  • Exit & Emergency Lighting Testing
  • General Electrical
  • Light (Lux) Level Metering
  • Microwave Testing
  • Safety Switch (RCD) Installation
  • Safety Switch (RCD) Testing
  • Relamping
  • Energy Efficient Lighting
  • Evacuation Plans
  • Fire Services

FAQs

Are you insured?

YES! We have current Public and Product Liability Insurance for $20,000,000.00 and Workers Compensation Insurance. Certificates of Currency for these are available apon request. We can also provide verification of our superannuation payments.

Are your technicians qualified to test my appliances?

YES! AS/NZS 3760, which is the relevant standard for safety checking of electrical appliances states that someone employed to do testing and tagging work of electrical appliances must be deemed "A competent person". This competency may be gained through training, experience or a combination of both.

All of our technicians meet the competency requirement set out by AS/NZS 3760. All of our technicians have obtained a TAFE statement in Safety Checking Electrical Appliances or an equivalent. They also gain experience through on the job training with other experienced technicians.

Do I need to test all of my appliances?

NO. Items that are deemed to be fixed or of low risk of being damaged do not need to be tested.

Do I need to test my flexible lead appliances?

YES! All employers have a duty of care to insure they are providing a safe working evirvonment for their staff members. The OH&S Act (2000) and OH&S Regulation (2001) are the current pieces of legislation that must be followed in regards to electrical appliance safety.

Do we need to test new appliances?

NO! New appliances do need not to be tested, they do however need to be tagged to indicate the date on which they were introduced into service. Once Appliance Test & Tag Services have performed your testing service you will be provided with Introduction to Service tags at no extra charge so that you may apply them to new appliances as you need them.

Do you test RCDs (Safety Switches)?

YES! We will perform a Millisecond and push button test on your RCDs and include this information into the Appliance Register that you will be provided after our service is completed.

Do you test three phase equipment?

YES! We test three phase (polyphase/415V) equipment at the same rate as single phase appliances.

How much do you charge?

We charge per appliance that we test. We do not charge extra for three phase equipment nor for powerboards. Our prices start from as low as $3.00 per appliance. Contact the friendly staff in our office for a quote.

How often do I need to test?

The testing interval depends on the environment in which the appliance is being used. The harsher the environment then the more likely the appliance is to be damaged, hence there is a requirement for a reduced time between testing. Please see the table below for a testing schedule for the most common environments.

Equipment type

Environment type

Class 1

Class 2

Powerboards &
Ext Leads

Domestic Construction
3 Months
3 Months
3 Months
Commercial Construction
1 Month
1 Month
1 Month
Factories and workshops
6 Months
12 Months
6 Months
Hostile Environment where the lead of the appliance is flexed during use or open to abuse
12 Months
12 Months
12 Months
NON Hostile Environment where the lead of the appliance is NOT flexed during use or is NOT open to abuse
5 Years
5 Years
5 Years
Residential Areas of hotels
2 Years
2 Years
2 Years
Commercial Cleaning Equipment
6 Months
12 Months
12 Months
Hire Equipment (Visual inspection before each hire)
3 Months
3 Months
3 Months
Repaired, serviced and second-hand equipment
After repair or service which could affect electrical safety, or on reintroduction to service.

What benefits do you offer over other testing services?

The following outlines the benefits our testing services compared to our competitors:

  • Unique Barcoding System
  • Electronic Data Capture
  • No additional charges for three phase (polyphase/415V) or powerboard testing
  • RCD Testing and reporting
  • Supply of your records in both electronic and printed formats
  • Supply of Introduction to Service tags at no extra cost

What does testing involve?

The process of testing appliance involves the following:
  • Visual Inspection: Firstly the appliance shall be checked to ensure that it is in good physical condition and there are no obvious signs of danger.
  • Electrical Testing: The appliance shall be tested with a Portable Appliance Tester (PAT) to test for any unseen electrical faults.
  • Record Keeping: Once the appliance is tested a record of the appliance and the test outcomes as well as who tested it shall be made.

DOWNLOADS

2010 Pelican Case Catalogue 2010 Pelican Case Catalogue

Aegis Patrol CZ5000 Brochure Aegis Patrol CZ5000 Brochure

Aegis Patrol PRO Aegis Patrol PRO

Kyoritsu 6201a Kyoritsu 6201a

Megger LCB2500 2 Megger LCB2500 2

Metrel AlphaPAT Metrel AlphaPAT

PAC-TPL 3 Phase Leakage Adaptor PAC-TPL 3 Phase Leakage Adaptor

Redback Ladders Redback Ladders

Sample Emergency Evacuation Plan Sample Emergency Evacuation Plan

SEW 4112EL SEW 4112EL

TestNTag iPhone Data Capture Solution Brochure TestNTag iPhone Data Capture Solution Brochure

TnT TnT

TnT Plus TnT Plus

TPL_Series_ATTS TPL_Series_ATTS

WinPATS Brochure WinPATS Brochure

WinPATS CE Brochure WinPATS CE Brochure

WinPATS Info WinPATS Info

General Electrical Services

General Electrical Services

ATTS do not only do testing and tagging, we have a team of fully qualified electricians who are able to perform any electrical installation/modifications works that you require.

  • New installations
  • Single and 3 phase services
  • Phase upgrades
  • Metering
  • Multiple commercial metering installations
  • Emergency and exit lighting
  • Switchboard upgrade & replacement
  • Uninterrupted Power Supply (UPS) to critical equipment
  • Corporate and commercial fit outs
  • Refurbishment and upgrades to existing premises
  • Additional lighting and power points to building additions and extensions
  • Switchboard installation and upgrade

Our staff have experience in a wide variety of commercial work places, retail outlets as well residential.

The majority of staff at ATTS are long term trusted employees that have worked in varying degrees of sensitive areas for a number of years as well as having current police checks to give the customer that additional peace of mind.

Please get in touch with the friendly staff in the office to organize a quote for any works you may need.

ATTS strongly recommends our clients consider the benefits of programmed maintenance. We emphasise the potential cost savings made possible through prevention of costly downtime in the event of equipment failure and minimization of irregular service calls for random fitting and equipment repairs. Our services include: Evacuation Lighting System testing & certification Appliance testing and tagging Thermal Scans and reports Lighting repairs Switchboard inspections and testing and various other servces

OUR CLIENTS

  • Company

    • About Us
    • Why Us?
    • FAQs
    • Downloads
    • Contact Us
  • Services

    • Appliance Test & Tag
    • Thermal Imaging
    • Exit & Emergency Lighting Testing
    • General Electrical
    • Light (Lux) Level Metering
    • Microwave Testing
    • Safety Switch (RCD) Installation
    • Safety Switch (RCD) Testing
    • Relamping
    • Energy Efficient Lighting
    • Evacuation Plans
    • Fire Services
  • Shop

    • Accessories
    • Adapters
    • Appliance Testers
    • Barcodes
    • Data Capture
    • Ladders
    • Meters
    • RCD Testers
    • Test Tags