FAQs

Are you insured?

YES! We have current Public and Product Liability Insurance for $20,000,000.00 and Workers Compensation Insurance. Certificates of Currency for these are available apon request. We can also provide verification of our superannuation payments.

Are your technicians qualified to test my appliances?

YES! AS/NZS 3760, which is the relevant standard for safety checking of electrical appliances states that someone employed to do testing and tagging work of electrical appliances must be deemed "A competent person". This competency may be gained through training, experience or a combination of both.

All of our technicians meet the competency requirement set out by AS/NZS 3760. All of our technicians have obtained a TAFE statement in Safety Checking Electrical Appliances or an equivalent. They also gain experience through on the job training with other experienced technicians.

Do I need to test all of my appliances?

NO. Items that are deemed to be fixed or of low risk of being damaged do not need to be tested.

Do I need to test my flexible lead appliances?

YES! All employers have a duty of care to insure they are providing a safe working evirvonment for their staff members. The OH&S Act (2000) and OH&S Regulation (2001) are the current pieces of legislation that must be followed in regards to electrical appliance safety.

Do we need to test new appliances?

NO! New appliances do need not to be tested, they do however need to be tagged to indicate the date on which they were introduced into service. Once Appliance Test & Tag Services have performed your testing service you will be provided with Introduction to Service tags at no extra charge so that you may apply them to new appliances as you need them.

Do you test RCDs (Safety Switches)?

YES! We will perform a Millisecond and push button test on your RCDs and include this information into the Appliance Register that you will be provided after our service is completed.

Do you test three phase equipment?

YES! We test three phase (polyphase/415V) equipment at the same rate as single phase appliances.

How much do you charge?

We charge per appliance that we test. We do not charge extra for three phase equipment nor for powerboards. Our prices start from as low as $3.00 per appliance. Contact the friendly staff in our office for a quote.

How often do I need to test?

The testing interval depends on the environment in which the appliance is being used. The harsher the environment then the more likely the appliance is to be damaged, hence there is a requirement for a reduced time between testing. Please see the table below for a testing schedule for the most common environments.

Equipment type

Environment type

Class 1

Class 2

Powerboards &
Ext Leads

Domestic Construction
3 Months
3 Months
3 Months
Commercial Construction
1 Month
1 Month
1 Month
Factories and workshops
6 Months
12 Months
6 Months
Hostile Environment where the lead of the appliance is flexed during use or open to abuse
12 Months
12 Months
12 Months
NON Hostile Environment where the lead of the appliance is NOT flexed during use or is NOT open to abuse
5 Years
5 Years
5 Years
Residential Areas of hotels
2 Years
2 Years
2 Years
Commercial Cleaning Equipment
6 Months
12 Months
12 Months
Hire Equipment (Visual inspection before each hire)
3 Months
3 Months
3 Months
Repaired, serviced and second-hand equipment
After repair or service which could affect electrical safety, or on reintroduction to service.

What benefits do you offer over other testing services?

The following outlines the benefits our testing services compared to our competitors:

  • Unique Barcoding System
  • Electronic Data Capture
  • No additional charges for three phase (polyphase/415V) or powerboard testing
  • RCD Testing and reporting
  • Supply of your records in both electronic and printed formats
  • Supply of Introduction to Service tags at no extra cost

What does testing involve?

The process of testing appliance involves the following:
  • Visual Inspection: Firstly the appliance shall be checked to ensure that it is in good physical condition and there are no obvious signs of danger.
  • Electrical Testing: The appliance shall be tested with a Portable Appliance Tester (PAT) to test for any unseen electrical faults.
  • Record Keeping: Once the appliance is tested a record of the appliance and the test outcomes as well as who tested it shall be made.

DOWNLOADS

2010 Pelican Case Catalogue 2010 Pelican Case Catalogue (18739 KB)

Aegis Patrol CZ5000 Brochure Aegis Patrol CZ5000 Brochure (681 KB)

Aegis Patrol PRO Aegis Patrol PRO (292 KB)

Kyoritsu 6201a Kyoritsu 6201a (48 KB)

Megger LCB2500 2 Megger LCB2500 2 (363 KB)

Metrel AlphaPAT Metrel AlphaPAT (113 KB)

PAC-TPL 3 Phase Leakage Adaptor PAC-TPL 3 Phase Leakage Adaptor (70 KB)

Redback Ladders Redback Ladders (2222 KB)

Sample Emergency Evacuation Plan Sample Emergency Evacuation Plan (253 KB)

SEW 4112EL SEW 4112EL (235 KB)

TestNTag iPhone Data Capture Solution Brochure TestNTag iPhone Data Capture Solution Brochure (1256 KB)

TnT TnT (925 KB)

TnT Plus TnT Plus (993 KB)

TPL_Series_ATTS TPL_Series_ATTS (541 KB)

WinPATS Brochure WinPATS Brochure (218 KB)

WinPATS CE Brochure WinPATS CE Brochure (235 KB)

WinPATS Info WinPATS Info (533 KB)

Exit & Emergency Lighting Testing

Exit & Emergency Lighting Testing

An exit sign is a device that displays the location of or direction to an emergency exit is located. They are a battery-backed lighting device that comes on automatically when a building experiences a power outage or in the event of fire.

In Australia, emergency and exit lights are standard in most modern Class 2 to Class 9 Buildings.

We supply, install as well as maintain Emergency & Exit Lights which are Essential Safety Measures in case of a fire & building compliancy ensuring an emergency exit lighting system is fully operational can prevent dangerous situations and offer an escape route in the event of an accident.

ATTS offer emergency exit light testing services to ensure the full compliance with Australian Standards AS2293.

The current Aust Std requires testing, inspection & recording of results every six months to comply with the Aust Building Code, Council & Fire regulations. On completion of these tests and repairs, certification is issued to comply with the above regulatory bodies.

ATTS are specialist in periodical inspection and testing of emergency exit lighting in schools, and business and commercial sites, ensuring companies fulfill their Occupational Health and Safety obligations and exercise their Duty of care.

Our electricians also carry a full range of different makes & models, and offer competitive pricing on all repairs. Onsite repairs can eliminate costly call out fees and onsite charges if completed on the day

The latest range of LED exit light fixtures is also available to reduce lamp failures with warranty offered on all parts & labour.

We also specialize in testing monitored and radio frequency controlled systems
We are familiar wih the following makes and there extensive range of fittings:

  • Bardic
  • Clevertronics
  • Coopers
  • Famco
  • Legrand
  • Minitronics
  • Stanilite
  • White Light industries

Another advantage of using ATTS Facilities Maintenance is we can inspect all your fire extinguishers & fire hydrants whilst on site as well as design & implement emergency & evacuation plans. This allows companies & business to streamline the amount of different service providers into a one company.

OUR CLIENTS

  • Company

    • About Us
    • Why Us?
    • FAQs
    • Downloads
    • Contact Us
  • Services

    • Appliance Test & Tag
    • Thermal Imaging
    • Exit & Emergency Lighting Testing
    • General Electrical
    • Light (Lux) Level Metering
    • Microwave Testing
    • Safety Switch (RCD) Installation
    • Safety Switch (RCD) Testing
    • Relamping
    • Energy Efficient Lighting
    • Evacuation Plans
    • Fire Services
  • Shop

    • Accessories
    • Adapters
    • Appliance Testers
    • Barcodes
    • Data Capture
    • Ladders
    • Meters
    • RCD Testers
    • Test Tags